articleCirculationAug 31, 2012BRONZE OA

A Prospective, Randomized Clinical Trial of Hemodynamic Support With Impella 2.5 Versus Intra-Aortic Balloon Pump in Patients Undergoing High-Risk Percutaneous Coronary Intervention

NewYork–Presbyterian Hospital

PubMed
Indexed incrossrefpubmed

Abstract

Background

Although coronary artery bypass grafting is generally preferred in symptomatic patients with severe, complex multivessel, or left main disease, some patients present with clinical features that make coronary artery bypass grafting clinically unattractive. Percutaneous coronary intervention with hemodynamic support may be feasible for these patients. Currently, there is no systematic comparative evaluation of hemodynamic support devices for this indication. METHODS AND RESULTS: We randomly assigned 452 symptomatic patients with complex 3-vessel disease or unprotected left main coronary artery disease and severely depressed left ventricular function to intra-aortic balloon pump (IABP) (n=226) or Impella 2.5 (n=226) support during nonemergent high-risk percutaneous coronary intervention. The primary end point was the 30-day incidence of major adverse events. A 90-day follow-up was required, as well, by protocol. Impella 2.5 provided superior hemodynamic support in comparison with IABP, with maximal decrease in cardiac power output from baseline of -0.04±0.24 W in comparison with -0.14±0.27 W for IABP (P=0.001). The primary end point (30-day major adverse events) was not statistically different between groups: 35.1% for Impella 2.5 versus 40.1% for IABP, P=0.227 in the intent-to-treat population and 34.3% versus 42.2%, P=0.092 in the per protocol population. At 90 days, a strong trend toward decreased major adverse events was observed in Impella 2.5-supported patients in comparison with IABP: 40.6% versus 49.3%, P=0.066 in the intent-to-treat population and 40.0% versus 51.0%, P=0.023 in the per protocol population, respectively.

Conclusions

The 30-day incidence of major adverse events was not different for patients with IABP or Impella 2.5 hemodynamic support. However, trends for improved outcomes were observed for Impella 2.5-supported patients at 90 days. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00562016.

Citation impact

845
total citations
FWCI
23.60
Percentile
100%
References
21
Citations per year

Authors

13

Topics & keywords

Keywords
  • Medicine
  • Impella
  • Percutaneous coronary intervention
  • Intra-aortic balloon pump
  • Hemodynamics
  • Cardiology
  • Randomized controlled trial
  • Internal medicine
UN Sustainable Development Goals
  • Good health and well-being
No related works found for this paper.