Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequences
Leeds General Infirmary · British Heart Foundation · +2 more institutions
Abstract
Sixty normal subjects (30 male and 30 female; age range, 20-65) were examined; both turbo gradient echo (TGE) and steady-state free precession (SSFP) pulse sequences were used to obtain contiguous short-axis cine data sets from the ventricular apex to the base of the heart. The LV and RV volumes and LV mass were calculated by modified Simpson's rule.
Normal ranges were established and indexed to both body surface area (BSA) and height. There were statistically significant differences in the measurements between the genders and between TGE and SSFP pulse sequences. For TGE the LV end-diastolic volume (EDV)/BSA (mL/m(2)) in males was 74.4 +/- 14.6 and in females was 70.9 +/- 11.7, while in SSFP in males it was 82.3 +/- 14.7 and in females it was 77.7 +/- 10.8. For the TGE the LV mass/BSA (g/m(2)) in males was 77.8 +/- 9.1 and in females it was 61.5 +/- 7.5, while in SSFP in males it was 64.7 +/- 9.3 and in females it was 52.0 +/- 7.4. For TGE the RV EDV/BSA (mL/m(2)) in males was 78.4 +/- 14.0 and in females it was 67.5 +/- 12.7, while in SSFP in males it was 86.2 +/- 14.1 and in females it was 75.2 +/- 13.8.
Citation impact
- FWCI
- 25.06
- Percentile
- 100%
- References
- 24
Authors
6- KAKhaled AlfakihCorresponding
Leeds General Infirmary, British Heart Foundation
- SPSven Plein
Leeds General Infirmary, British Heart Foundation
- HTHölger Thiele
Leipzig Heart Institute, Leipzig University
- TRTim R. Jones
Leeds General Infirmary, British Heart Foundation
- JPJohn P. Ridgway
Leeds General Infirmary
Topics & keywords
- Steady-state free precession imaging
- Ventricular volume
- Magnetic resonance imaging
- Body surface area
- Precession
- Medicine
- Nuclear magnetic resonance
- Cardiology