O-(2-[18F]fluoroethyl)-L-tyrosine PET combined with MRI improves the diagnostic assessment of cerebral gliomas
Indexed incrossrefpubmed
Abstract
MRI is commonly used to determine the location and extent of cerebral gliomas. We investigated whether the diagnostic accuracy of MRI could be improved by the additional use of PET with the amino acid O-(2-[18F]fluoroethyl)-l-tyrosine (FET). In a prospective study, PET with FET and MRI was performed in 31 patients with suspected cerebral gliomas. PET and MRIs were co-registered and 52 neuronavigated tissue biopsies were taken from lesions with both abnormal MRI signal and increased FET uptake (match), as well as from areas with abnormal MR signal but normal FET uptake or vice versa (mismatch). Biopsy sites were labelled by intracerebral titanium pellets. The diagnostic performance for the identification of…
Citation impact
636
total citations
- FWCI
- 9.41
- Percentile
- 100%
- References
- 42
Citations per year
Authors
1Topics & keywords
Topics
Keywords
- Medicine
- Glioma
- Biopsy
- Magnetic resonance imaging
- Receiver operating characteristic
- Nuclear medicine
- Pathology
- Radiology
No related works found for this paper.