articleNov 8, 2002Closed access
Stationary frame generalized integrators for current control of active power filters with zero steady state error for current harmonics of concern under unbalanced and distorted operation conditions
École Polytechnique Fédérale de Lausanne · ETH Zurich · +1 more institution
Indexed incrossref
Abstract
The paper proposes several concepts of integrators for sinusoidal signals. Parallel and series associations of the basic PI units using the stationary frame generalized integrators are used for current control of active power filters. Zero steady state error for the concerned current harmonics are realized, with reduced computation, under unbalanced utility or load conditions. Designing of the PI constants, digital realization of the generalized integrators, as well as compensation of the computation delay etc. are studied. Extensive test results from a 10 kW active power filter prototype are demonstrated.
Citation impact
666
total citations
- FWCI
- 11.88
- Percentile
- 100%
- References
- 30
Citations per year
Authors
4Topics & keywords
Topics
Keywords
- Integrator
- Control theory (sociology)
- Harmonics
- Stationary Reference Frame
- Active filter
- Realization (probability)
- Current (fluid)
- Compensation (psychology)
UN Sustainable Development Goals
- Affordable and clean energy
No related works found for this paper.