Constant boost control of the Z-source inverter to minimize current ripple and voltage stress
Michigan State University · Ford Motor Company (United States) · +3 more institutions
Indexed incrossref
Abstract
This paper proposes two constant boost-control methods for the Z-source inverter, which can obtain maximum voltage gain at any given modulation index without producing any low-frequency ripple that is related to the output frequency and minimize the voltage stress at the same time. Thus, the Z-network requirement will be independent of the output frequency and determined only by the switching frequency. The relationship of voltage gain to modulation index is analyzed in detail and verified by simulation and experiments.