articleIEEE Transactions on Power ElectronicsJul 1, 2004GREEN OA

Fault Tolerant Three-Phase AC Motor Drive Topologies: A Comparison of Features, Cost, and Limitations

General Motors (United States) · University of Wisconsin–Madison

Indexed incrossref

Abstract

This paper compares the many fault tolerant three-phase ac motor drive topologies that have been proposed to provide output capacity for the inverter faults of switch short or open-circuits, phase-leg short-circuits, and single-phase open-circuits. Also included is a review of the respective control methods for fault tolerant inverters including two-phase and unipolar control methods. The output voltage and current space in terms of dq components is identified for each topology and fault. These quantities are then used to normalize the power capacity of each system during a fault to a standard inverter during normal operation. A silicon overrating cost factor is adopted as a metric to compare the relative…

Citation impact

718
total citations
FWCI
18.63
Percentile
100%
References
34
Citations per year

Authors

4

Topics & keywords

Keywords
  • Inverter
  • Network topology
  • Topology (electrical circuits)
  • Fault (geology)
  • Control theory (sociology)
  • Fault tolerance
  • Electronic circuit
  • Electronic engineering
UN Sustainable Development Goals
  • Affordable and clean energy
No related works found for this paper.