Coronary CT Angiography with Photon-counting CT: First-In-Human Results
Université Claude Bernard Lyon 1 · Centre National de la Recherche Scientifique · +11 more institutions
Abstract
Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65–75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based…
Citation impact
- FWCI
- 22.14
- Percentile
- 100%
- References
- 28
Authors
22- SSSalim Si‐MohamedCorresponding
Université Claude Bernard Lyon 1, Centre National de la Recherche Scientifique, Inserm, Hospices Civils de Lyon, Hôpital Louis Pradel, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé, Institut National des Sciences Appliquées de Lyon
- SBSara Boccalini
Université Claude Bernard Lyon 1, Centre National de la Recherche Scientifique, Inserm, Hospices Civils de Lyon, Hôpital Louis Pradel, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé, Institut National des Sciences Appliquées de Lyon
- HLHugo Lacombe
Université Claude Bernard Lyon 1, Centre National de la Recherche Scientifique, Inserm, Hospices Civils de Lyon, Hôpital Louis Pradel, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé, Institut National des Sciences Appliquées de Lyon
- ADAdja Diaw
Université Claude Bernard Lyon 1, Centre National de la Recherche Scientifique, Inserm, Hospices Civils de Lyon, Hôpital Louis Pradel, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé, Institut National des Sciences Appliquées de Lyon
- MVMohammad Varasteh Anvar
Université Claude Bernard Lyon 1, Centre National de la Recherche Scientifique, Inserm, Hospices Civils de Lyon, Hôpital Louis Pradel, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé, Institut National des Sciences Appliquées de Lyon
Topics & keywords
- Medicine
- Interquartile range
- Confidence interval
- Coronary artery disease
- Nuclear medicine
- Radiology
- Image quality
- Imaging phantom
- Good health and well-being