articleAtmospheric measurement techniquesApr 5, 2022GOLD OA

Sentinel-5P TROPOMI NO 2 retrieval: impact of version v2.2 improvements and comparisons with OMI and ground-based data

Royal Netherlands Meteorological Institute · Royal Belgian Institute for Space Aeronomy · +3 more institutions

Indexed incrossrefdoaj

Abstract

Abstract. Nitrogen dioxide (NO2) is one of the main data products measured by the Tropospheric Monitoring Instrument (TROPOMI) on the Sentinel-5 Precursor (S5P) satellite, which combines a high signal-to-noise ratio with daily global coverage and high spatial resolution. TROPOMI provides a valuable source of information to monitor emissions from local sources such as power plants, industry, cities, traffic and ships, and variability of these sources in time. Validation exercises of NO2 v1.2–v1.3 data, however, have revealed that TROPOMI's tropospheric vertical column densities (VCDs) are too low by up to 50 % over highly polluted areas. These findings are mainly attributed to biases in the cloud pressure…

No related works found for this paper.

Funding