articleIEEE Transactions on Power ElectronicsJul 18, 2023Closed access

A MTPA and Flux-Weakening Curve Identification Method Based on Physics-Informed Network Without Calibration

Huazhong University of Science and Technology

Indexed incrossref

Abstract

In order to improve the efficiency, interior permanent magnet synchronous motors (IPMSMs) or the synchronous reluctance motors (SynRMs) need to be calibrated to obtain the maximum torque per ampere (MTPA) and flux-weakening (FW) curves. In industrial application, there are different types of IPMSMs and SynRMs. It is expensive and time-consuming to build test benches to calibrate each motor. In this letter, a physics-informed network is proposed to obtain the MTPA and FW operating curves. Only data from accelerating experiment, when motor operates without load, are adopted. The test bench is unnecessary. Experimental results show the validity of proposed method.

Citation impact

291
total citations
FWCI
12.93
Percentile
100%
References
8
Citations per year

Authors

4

Topics & keywords

Keywords
  • Magnetic reluctance
  • Ampere
  • Calibration
  • Test bench
  • Torque
  • Control theory (sociology)
  • Identification (biology)
  • Magnet
UN Sustainable Development Goals
  • Affordable and clean energy
No related works found for this paper.